Avocent Cyclades-PR4000 User Manual

Page 129

Advertising
background image

129

Cyclades-PR4000

Chapter 14 - Filters and Rules

Filter_list Name exterior_out
Rule 0
Status

Enabled

Scope

Permit

Protocol

TCP

Source IP Operator

Equal

Source IP start

192.168.0.3

Source IP Mask

255.255.255.255

Destination IP Operator

None

Source Port Operator

Equal

Source Port Start

SMTP

Destination Port Operator

Greater than

Destination Port Start

1023

TCP connections allowed

N

Account Process allowed

N

FIGURE 12.4 OUTPUT FOR IP FILTERING EXAMPLE

Interior Router

If an interior router exists in the network, the administrator may decide to use a

Default Scope of Permit. In this

case, all undesired traffic must be excluded by a rule in the rule list. In Figure 12.5, a conceptual equivalent of
the interface is shown.

All packets except those which fall into the holes in the ball will be allowed entry in to or out of the network.