HOW TO OPERATE

To start the operation

• Press 1.
• POWER indicator (green) on the indoor unit will light up.
• To stop, press once more.

Setting Mode

• Press 2 to select:-

Cooling Model

AUTO

– Automatic Operation

COOL

– Cooling Operation

DRY

– Soft Dry Operation

FAN

– Air Circulation Operation

Heat Pump Model

AUTO

– Automatic Operation

HEAT

– Heating Operation

COOL

– Cooling Operation

DRY

– Soft Dry Operation

PREPARATION BEFORE OPERATION

Indoor Unit

1

Connect the power supply cord to an independent
power supply.

Setting Temperature

• Press 3 to increase or decrease the temperature.
• The temperature can be set between 16°C ~ 30°C
• Recommended temperature:

• During AUTO Operation, press 3 to select:-

Operation with 2°C higher than the standard
temperature.

Operation with the standard temperature.

Operation with 2°C lower than the standard
temperature.

Standard Temperature

Cooling Model

• Once the Automatic Operation is selected, the indoor

temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.

• After the operation mode has been selected, the

mode does not change.

Heat Pump Model

• At the beginning of the automatic operation, Heating,

Cooling or Soft Dry is automatically selected according
to the indoor temperature.

• After the operation mode has been selected, the

mode does not change.

Operation

Cooling

Soft Dry

Standard

temperature

25°C

22°C

Indoor

temperature

23°C

Operation

Cooling

Soft Dry

Heating

Standard

temperature

25°C

22°C

21°C

Indoor

temperature

23°C

20°C

Cooling Model

COOL –> 26°C ~ 28°C

DRY

–> 1°C ~ 2°C
lower than the
room temperature

Heat Pump Model

COOL –> 26°C ~ 28°C

DRY

–> 1°C ~ 2°C
lower than the
room temperature

HEAT –> 20°C ~ 24°C

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.

During Soft Dry operation, the indoor fan operates at
Low Fan Speed.

HEAT – Heating Operation
(for Heat Pump Model only)

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.

Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.

FAN – Air Circulation Operation
(for Cooling Model only)

Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.

At ceiling mounted

At floor mounted