ENGLISH

7

OFF/ON

TEMP

MODE

FAN SPEED

AUT

O

TIMER

AIR SWING

RESET

AU

TO

COOL

FA

N

FA

N

SPEED

DR

Y

C

H

H

O

FF

O

N

O

FF

O

N

SLEEP

3

2

1

4

5

SELECT

SET/CANCEL

A

B

CONVENIENCE OPERATION

Sleep Mode Operation

To obtain a comfortable room temperature while sleeping:-
• Press 5.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.

Sleep Mode Operation Details

• When the room temperature reaches the set temperature,

the airflow volume will change to low automatically.

• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a priority.

Cooling Model

CARE AND MAINTENANCE

Cleaning the Indoor Unit and Remote

Control

• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid

to clean the unit.

Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)

1

Remove dirt using a vacuum cleaner.

2

Wash back of the air filter with water.

3

If badly soiled, wash it with soap or a mild household
detergent.

4

Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.

* Damaged air filter.

Consult the nearest authorized dealer.
Part No.: CWD001088.

• Do not use benzene, thinner, scouring powder or

clothes soaked in caustic chemical to clean the
unit.

H

OFF

H

ON

H

ON

H

OFF

H

ON

H

OFF

SETTING THE TIMER

• Press the Timer Selection Button 1.
• Timer indicator on the indoor unit will light up.
• Select one of the following five types of operation.

Each time the button is pressed, the operation mode
is shifted in the arrow direction.

Delay OFF Timer

Example :
Operation Stops
after 1 hour
ON Timer.

Delay ON Timer

Example :
Operation starts after
6 hours.

Delay OFF and

Example :

ON Timer

Operation stops after
1 hour and re-starts
after another 5 hours.

Delay ON and

Example :

OFF Timer

Operation starts after
10 hours, and then
stops after another 8
hours.

• Then press the Timer Setting Button 2 or 3 to the

desired number of hours.
(Number of hours which can be set : 1 ~ 12)

• Press the Timer Set/Cancel Button 4.

Heat Pump Model

← 1 hour →

Sleep shift
operation starts.

Approx. 3°C
decrease.

• Cooling or Soft Dry

Operation for sleep shift
operation will start to
avoid overcooling.

• Heating operation for

sleep shift operation will
start to avoid overheating.

Sleep
Operation
button is
pressed.

0~1 hour

Approx. 2°C
decrease.

Approx.
0.5°C
increase.

Approx. 0.5°C
increase.

Temperature

S
e

t
t
i

n
g

T
e

m

p
e

r

a

t

u

r

e

Time

← 1 hour →

after approx. 8 hours of sleep shift
operation, it will stop automatically.

Time

Approx. 0.5°C
increase.

Temperature

Sleep
Operation
button is
pressed.

Sleep shift
operation
starts.

0~1 hour

← 1 hour →

after approx. 8 hours of sleep shift

operation, it will stop automatically.

Approx.
0.5°C
increase.

• Cooling or Soft Dry

Operation for sleep shift
operation will start to
avoid overcooling.

S
e

t
t
i

n
g

T
e

m

p
e

r

a

t

u

r

e

12CTP5-01EN(01-09)

12/24/09, 11:29 AM