Initialise new label material, Als 230, 3 initialise new label material – Avery ALS 230 User Manual

Page 27

Advertising
background image

Operators Manual

ALS 230

Release 11/05

Page 25

Operation

4.3 Initialise new label material

The machine requires data of the label material in use i.e. label length and opacity of the label
and backing material. In most cases, those parameters can be scanned during automatic
initialisation. This is not always possible.
During initialisation, the machine uses its label sensor to determine where the labels are on the
label web and the distance between the leading edge of labels (the label pitch) so that they can
be positioned correctly.

There are several modes of initialisation:

y

Automatic mode: The machine measure the setting

y

Manual mode: The operator measures the label parameter and keys in the values.

In most cases, initialisation should be executed in fully automatic mode. For fully automatic
initialisation, the "LPIT" and "CONT" parameters should be set to "AUTO". Initialisation can be
executed by pressing the <FEED key> whenever the message "INIT" is displayed by the
machine.

The message "INIT" is displayed in the following cases:

a) if the <FEED> key is pressed and held during power up
b) on return to the standard menu after the "CONT" or "LPIT" parameters have been changed

to automatic mode

c) on return to the standard menu after the configuration menu has been used
d) after clearing the error messages E__0 or E__1 in the standard menu. (If the feed key is

pressed while another parameter is displayed, the data from the last initialisation is held
and the first label edge detected is simply moved to the position defined by the "STOD"
parameter)


To start initialisations simply press the <FEED> key when "INIT" is displayed.
The machine will slowly feed the label web while it searches for the gaps between labels and
measures the label pitch. When the machine has determined this information it will move the
first label edge found during the initialisation process to the position that has been adjusted with
the "STOD" parameter. After initialisation has been completed successfully, "ON" is displayed.
Initialisation can only take place in the standard menu; it is not required in the product menu
since all label data is already stored in the machine's memory. After a E__0 or E__1 message
has been cleared whilst in the product menu the first label edge detected at the next press of
the <FEED> key will be moved to the position defined by the "STOD" value stored in the
machine's memory.
However, when changing to a new product bank or changing label rolls the FEED key should
be pressed once so that the label sensor can find the next leading label edge and move it to the
correct dispense position previously defined by the STOD parameter