Applicator modes, Signals for direct dispense, Als 230 – Avery ALS 230 User Manual

Page 58: 2 applicator modes

Advertising
background image

Operators Manual

ALS 230

Release 11/05

Page 56

Connections and signals

8.2 Applicator modes

The machine is able to dispense the label direct on the passing product. There is also the
possibility to drive without any external control a wide range of applicators.

8.2.1

Signals for direct dispense

For direct dispensing the airstream signal can be used to control a pneumatic driven dispensing
edge. The start of the airstream signal (= motor run signal) could be behind the start of the
dispense motor, adjusted with the function APT3. The signal is switched inactive, when the
label dispense has been completed. Also the stop could be adjusted with the function ASTP to
switch inactive before or behind the dispense motor stop.

Ready

Product start

Label start
Suppression

Product start
Suppression

Dispense

Motor run
signal

1

2

3

4

POS

POS

POS

PRDL

APT3

ASTP

ASTP

1

Productstart disabled. PRDL activ

2

Missing Label: New start of dispense during dispenser activ

3

Inhibit activ

4

Machine not ready. Errorcondition or not online

Figure 10 Timing diagram direct dispense

Advertising