Apsf sensor, Als 230, Operators manual – Avery ALS 230 User Manual

Page 65: 3 apsf sensor

Advertising
background image

Operators Manual

ALS 230

Release 11/05

Page 63

Connections and signals

8.3.3 APSF

sensor

For the APSF function (Automatic speed follower) a rotary encoder has to be installed. For
optimum labelling accuracy the rotary encoder should be selected so that it produces one pulse
for every 0.125 mm of product movement. The connection of the encoder should be done with
a shielded cable. For correct operation the rise and fall time of the encoder signal should be
1 µs.

+24V

GND

14

black

yellow

white
red

5
9
4
8
3
7
2
6

1

GND

Signal

Supply

Shield

12

33
27

CN33

NPN sensor

5
9
4
8
3
7
2
6

1

Figure 19 Connection of a NPN type APSF sensor

+24V

GND

14

black

yellow

white
red

12

33
27

CN33

5
9
4
8
3
7
2
6

1

5
9
4
8
3
7
2
6

1

GND

Signal

Supply

Shield

PNP sensor

Figure 20 Connection of a PNP type APSF sensor