SE-4200/4400 WATER FILTRATION SYSTEM

10

P/N 1010852 Rev. C 04/06

OPERATION

Filtration Process

The filtration process includes a Filtration Cycle and a

Backwash Cycle.

During the Filtration Cycle, water enters the system

inlet port and passes through the filter elements before

exiting via the Permeate outlet.

This system is designed so that no valves are powered

during the Filtration Cycle. This allows water to contin-

ue to be filtered during a power outage and it minimizes

electrical power consumption.

After a period of time, the filters have to be cleaned.

This is accomplished through the Backwash Cycle.

During the Backwash Cycle, filtered water from one of

the cartridges is fed back through the other cartridge to

break up any debris collected on the membrane walls.

The Backwash Cycle includes a forward flush step

which then uses the feed water to flush away the loos-

ened debris from the cartridge’s membranes. The

valves are only powered during the flushing cycle and

in STOP MODE.

NOTE: Both the Filtration and Backwash cycles

can be completely automated through the Control

Panel. See the Programming section within this

manual.

Control

Button

Function

FLUSH

Performs a QUICK FLUSH operation

when actuated during FILTER MODE or

STOP MODE.

RUN

Initializes and starts an internal timer for

the automatic flushing of the system and

puts the system into FILTER MODE.

When pressed, the system performs a

BORE AIR RELEASE operation before

entering FILTER MODE.

STOP

Stops all functions immediately; pow-

ers all valves. Closes the Input and

Permeate ports/valves and opens all

Drain ports/valves.

F1

Starts the Backwash Cycle during

FILTER MODE or STOP MODE.

F2

Service Feature. Valve, Transducer,

and alarm status can be viewed and

changed. Press and hold this button for

a minimum of 3 seconds to access this

mode.

CURSOR

Up/Down/Left/Right arrow buttons

are used to scroll through the choices

shown in the Message Display window.

MENU

Allows access to program and setting

features .

ENTER

Used to confirm settings in MENU

mode.

Operating Controls (Figure 2)

Message Display

FLUSH

RUN

F1

F2

STOP

MENU

ENTER

Figure 2. Operating Controls