Programming, Operation (continued) – Antunes, AJ SE-4200/4400 User Manual

Page 11

Advertising
background image

SE-4200/4400 WATER FILTRATION SYSTEM

11

P/N 1010852 Rev. C 04/06

OPERATION (continued)

Programming

1. Once the system is connected to a power source,

the unit displays the following messages in the

table below in order:

Message

Description

ANTUNES FILTRATION
Rev. 00.00.00

Shows the software and

hardware revision informa-

tion.

ver- BASIC ON:lcd ON
units- US:audio ON

Indicates the system hard-

ware setup.

BORE AIR RELEASE
00:05 mm:ss

Indicates the unit is filling

filters with water.

STOP MODE
00/00/00 00:00:00 AM

Indicates the controller is

performing internal tests to

verify correct filter operation.

FILTER MODE
00/00/00 00:00:00 AM

Indicates the unit is in

FILTER MODE.

After the system displays the FILTER MODE message,

proceed to the next step.

NOTE: Only a few items need to be programmed

to allow for the proper operation of the system.

Default values in the system programming are set

to automatically flush the filter cartridges for 1 min-

ute every hour. Default values should be sufficient

for most locations’ filtration needs.

NOTE: To skip a value, accept a default value, or to

save a changed value, you MUST press the Enter

button to save the entry and proceed to the next

option. If you make a mistake, press the Menu but-

ton to go back to the previous display.

SET DATE/TIME MODE

NOTE: The Date and Time must be set in order for

proper system operation.

1. If the system does not already display the SET

DATE/TIME

message, from the FILTER MODE,

press the Stop button. The system enters STOP

MODE and displays STOP MODE on the display.

2. Press the Menu button.

3. Using the Up and Down arrow buttons, scroll from

SET PASSWORD

to SET DATE/TIME and press

the Enter button.

4. The system displays the SET DATE message.

Using the Up and Down arrow buttons, enter the

correct date in mm/dd/yy format. After each entry,

press the Enter button. For example, for June, set

the month as 06 and then press the Enter button.

Set the date and year in this same manner.

5 The system then displays the SET TIME message.

Using the Up and Down arrow buttons, enter the

correct hour in hh format and press the Enter but-

ton. Then, enter the correct minutes in mm format

and press the Enter button. Finally, select AM or

PM and press the Enter button.

6. After setting the date and time, the system dis-

plays the SET DATE/TIME message. If you need

to make a correction to your settings, you can

press the Enter button and make any changes. If

the settings are correct, press the Menu button to

return to the STOP MODE function. The correct

date and time should be displayed.

7. Press the Run button to return to the FILTER

MODE function.

SET FILL FUNCTION MODE (BORE AIR RELEASE)

1. From the FILTER MODE display, press the Stop

button. The system displays the STOP MODE

message.

2. Press the Menu button.

3. Using the Up and Down arrow buttons, scroll from

SET PASSWORD

to SET FILL FUNCTION. Press

the Enter button.

4. The system displays the BORE AIR RELEASE

message. The default time is displayed as

00:05

seconds, which should be sufficient for

most locations. To change this setting, use the

Up and Down arrow buttons and the Enter key

to make the change. For example, to change the

setting to six, press the Enter button until the cur-

sor is in the fourth position and use the Up/Down

arrow buttons to change the setting to the desired

time.

5. Next, the system displays the SET FILL

FUNCTION

display. If you need to make a cor-

rection to the Fill Function setting, press the Enter

button to do so. If the setting is correct, Press

the Menu button to save the setting and return to

STOP MODE.

6. Press the Run button to return to FILTER MODE.