Installation (continued) – Antunes, AJ SE-4200/4400 User Manual

Page 9

Advertising
background image

SE-4200/4400 WATER FILTRATION SYSTEM

9

P/N 1010852 Rev. C 04/06

CAUTION

Ingesting the protective solution may cause irrita-

tion of the gastrointestinal tract, colic, diarrhea, or

other similar symptoms

INSTALLATION (continued)

SANITIZING THE SYSTEM AND LINES

The plumbing must also be sanitized to eliminate pos-

sible contamination that may have occurred during the

installation process. Chlorine bleach can be used to

sanitize the plumbing. The amount of bleach to use

depends on the system being installed, and the amount

of plumbing downstream of the filter system. Generally,

1 or 2 cap fulls of bleach will be sufficient to sanitize

the system. This can be done before the system final

connections are made or after the system has been

installed and flushed.

1. Open the faucet or tap closest downstream to the

filter system.

2. Close the inlet water valve and allow the system

to depressurize.

3. Place a bucket under the inlet connection to the

system. Disconnect the inlet pipe from the sys-

tem. Water will flow out the pipe as the system

drains.

4. When the water flow out of the pipe stops, pour

the liquid bleach into the pipe. Reattach the

plumbing to the system inlet.

5. Slowly open the inlet water valve to re-pressurize

the system. Allow water to flow out the tap until

the smell of bleach is present.

6. Close the tap and let the system stand with no

water flow for at least 15 minutes to allow the

bleach to sanitize the pipes.

7. After 15 minutes without flow, open the tap and

flush until the presence of bleach is gone. All

other taps should be opened to flush any bleach

from the plumbing.

8. Close the tap. The sanitization is complete.

Program the other controller features following the

steps within the Operation section of this manual.

CAUTION

Be careful when handling bleach. Follow all warn-

ings and precautions on the bleach packaging.

Do not mix Bleach with any other cleansers or

sanitizers.

FLUSHING AND STARTING THE SYSTEM

To ensure that the highest quality water is produced

from the system, the plumbing leading from the filter

system must be flushed clear of all debris after the

system is hooked up. After making the connection to

the outlet of the filter system, open a faucet or tap clos-

est to the filter system, then slowly open the inlet water

valve. Allow the pipe to flush until all debris is removed.

The unit also must be flushed to remove air and the

shipping/storage solution. For maximum quality, the

permeate water produced during the flushing procedure

must be discarded. Direct this permeate water to drain.

1. Plug the power cord into the appropriate electrical

outlet.

2. Follow the programming steps as outlined in the

Operation section of this manual.

3. Open the tap or faucet closest downstream to the

filter system.

4. Slowly open the inlet water valve and allow water

to enter the system.

5. Press the Run button. The drain valves will open

to flush the air out of the center of the hollow

fibers. Check to make sure that the drain water is

directed into the drain without splashing.

6. The drain valves will close automatically. Water

should continue to flow through the system and

out of the open tap. Allow water to flow out of the

tap for at least 15 minutes at maximum flow rate.

7. Close the tap and let the system stand with no

water flow for 15 minutes to allow any trapped air

to come out of the hollow fibers. Check for leaks

at all fittings.

8. After 15 minutes without any flow, open the tap for

5 minutes to allow any trapped air to be flushed

out.

9. Close the tap. The flushing is complete.

Advertising