Troubleshooting – Antunes, AJ SE-4200/4400 User Manual

Page 17

Advertising
background image

SE-4200/4400 WATER FILTRATION SYSTEM

17

P/N 1010852 Rev. C 04/06

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Unit does not have power. The power cord is not correctly plugged

in.

Plug power cord in correctly.

The Control Display is

blank.

The power cord is not correctly plugged

in.

Plug power cord in correctly.

Control Board is inoperable.

Contact your maintenance person or

Authorized Service agency.

Transformer is inoperable.

No water comes out of the

filter system.

Unit in “STOP” mode

Set unit to “RUN” mode.

Optional Inlet Valve (if installed) is

closed.

Open Inlet Valve.

Optional Prefilter (if installed) is plugged. Clean/replace Prefilter.
Optional Check Valve (if installed) is

stuck closed.

Clean/replace Check Valve.

End of capillaries plugged.

Clean/replace cartridge.

Valve/Controller Malfunction.

Replace Valve(s)/ Controller.

Low water flow/pressure

out of system.

See above.

See above.

System is flushing.

Wait for flush cycle to end.

Flushing program set incorrectly for

water conditions.

Decrease the Flush interval and increase

the flush duration.

Drain valve(s) stuck open.

Replace/rebuild valve(s).

Low inlet water pressure.

Boost pressure/replace pipes.

Water tastes bad.

Storage/Shipping solution not complete-

ly flushed out.

Flush system longer.

Biological growth in pipes.

Sanitize plumbing.

Water conditions have changed.

Consider installing a taste and odor filter.

Broken Capillary in cartridge

Replace cartridge.

Flush runs continuously.

Drain Valve(s) stuck open.

Replace/rebuild valve(s).

Controller sending continuous signal to

valve(s).

Replace Controller.

Flush runs too long.

Program duration set too long.

Change flush duration.

Flush occurs at time of

high water usage.

Interval flush set to interfere with high

water usage.

Change interval program time, or consider

time of day flush.

Time of day flush set to interfere with

high water use.

Chance time of day for flush to non-peak

water usage time.

Water splashes at drain

during flush.

Drain line not positioned properly.

Reposition end of drain line.

Water leaks at ends of

cartridge after changing

cartridge.

Cartridge end connections not tight.

Tighten with strap wrench if necessary.

O-rings not lubricated.

Lubricate O-ring with a food-grade lubri-

cant.

O-rings split, cut, or twisted.

Replace O-rings.

Advertising