OPERATION (continued)

SET QUICKFLUSH MODE

NOTE: The Quick Flush function allows the sys-

tem to be used for water systems containing a

high quantity of air. Air does not pass through the

filtration membranes. Performing a quick flush

at pre-set times allows the accumulated air to be

released.

1. From the FILTER MODE display, press the Stop

button. The system switches to STOP MODE and

displays the STOP MODE display.

2. Press the Menu button.

3. Using the Up and Down arrow buttons, scroll from

SET PASSWORD

to SET QUICKFLUSH and press

the Enter button.

4. The system displays the QUICKFLUSH ENABLE

display. The default value is off. Use the Left

and Right arrow buttons to toggle between on and

off

. When the value is set to on, press the Enter

button.

5. The system displays the QKFLUSH INTERVAL

display. The default interval value is 00:15 (or

fifteen minutes). This value should be appropri-

ate for most locations. To change this value, use

the Up and Down arrow buttons to enter the time

interval in hours and minutes (hh:mm). After each

entry, press the Enter button.

6. Next, the system displays the QKFLUSH LENGTH

display. The default length value is 00:15 (or fif-

teen seconds). Again, this should be appropriate

for most locations. To change this value, use the

Up and Down arrow buttons to enter the desired

flush interval in hours and minutes (mm:ss). After

each entry, press the Enter button.

7. The system displays the SET QUICKFLUSH dis-

play. If you need to correct your settings, press

enter and reset the values accordingly. If the

information is correct, press the Menu button to

return to STOP MODE.

8. Press the Run button to return to the FILTER

MODE

display.

SET FLUSH CYCLE MODE

1. From the FILTER MODE display, press the Stop

button. The system switches to STOP MODE and

displays the STOP MODE display.

2. Press the Menu button.

3. Using the Up and Down arrow buttons, scroll from

SET PASSWORD

to SET FLUSH CYCLE. Press the

Enter button.

4. The system displays the ACTIVATE FLUSH BY

display. Accept the default value of automatic.

IMPORTANT

The ACTIVATE FLUSH BY setting should ALWAYS

be set to “automatic” unless instructed by the

manufacturer. If your system is in “manual”

mode, use the Left and Right arrow buttons to

set this value back to the “automatic” setting and

press the Enter button.

5. The system displays the FLUSH BY INTERVAL

display. The default value for this setting is on.

This setting should be appropriate for most loca-

tions. If desired, use the Left and Right arrow

buttons to change the setting to off. Press the

Enter button.

If the FLUSH BY INTERVAL setting is set to on,

the system prompts for the interval setting. The

default interval is 001:00 (or one hour) in hhh:mm

format. To change this setting, use the Up and

Down arrow buttons to change the interval time.

After each entry, press the Enter button.

If the FLUSH BY INTERVAL value is set to off,

press the Enter button. The system displays the

FLUSH BY TIME OF DAY

message. The default

for this value is off. This should be changed to

on

using the Right and Left arrow buttons. After

the entry is set to on, press the Enter button.

NOTE: If the FLUSH BY TIME OF DAY option is set

to “off,” the system displays the FLUSH BY PRESS

DIFF display. Step 6 will be necessary ONLY if the

FLUSH BY TIME OF DAY option is set to “on.”

6. Next, the system prompts for the desired flush

time of day. Using the Up and Down arrow but-

tons, set the desired time of day for the system

flush in hh/mm and AM or PM. After each entry,

press the Enter button.