Installation, Unpacking, Equipment setup – Antunes, AJ SE-4200/4400 User Manual

Page 7: Suggested tools and supplies for installation

Advertising
background image

SE-4200/4400 WATER FILTRATION SYSTEM

7

P/N 1010852 Rev. C 04/06

CAUTION

Water Pressure must not exceed 7 bar (100 psi).

To reduce water pressure, install a water pressure

regulator and set water pressure to suit applica-

tion. Note that the trans membrane pressure

must be .5 - 3 bar (7.25 - 43.5 psi).

CAUTION

This equipment is to be installed to comply with

the basic plumbing code of the Building Officials

and Code Administrators, INC. (BOCA) and the

Food Service Sanitation Manual of the Food and

Drug Administration (FDA).

Unpacking

The carton should contain the filtration system and an

information packet.

• SE-4200 or SE-4400

• Information Packet

1. Remove unit and all packing materials from ship-

ping carton.

2. Remove all packing materials and protective cov-

erings from the unit.

2. Remove the information packet. To prevent delay

in obtaining warranty coverage, fill out and mail

the warranty card.

NOTE: If any parts are missing or damaged, con-

tact Antunes Filtration Technologies IMMEDIATELY

at 1-800-253-2991 (toll free in the U.S.) or 630-784-

1000.

Equipment Setup

GENERAL

When placing the unit into service, pay attention to the

following guidelines.

• Make sure power to the unit is off.

• Do not immerse the power cord or plug in water.

• Keep power cord away from heated surfaces.

ELECTRICAL

Ensure that the line voltage corresponds to the stated

voltage on the units specification label. Make sure

that the plug on the power cord from the system and

the outlet match. For proper operation of the system,

and to ensure the highest quality of water from the sys-

tem, make sure that the system is not connected to a

switched electrical outlet.

An ABC-type fuse (6 Amp, 250 VAC) is located inside

the control box.

PLUMBING

NOTE: This unit is designed to use tap water not to

exceed 104º F (40º C).

The SE Series uses the following connections:

• Water Inlet (Feed Water)

3/4” NPT

• Permeate (Product Water)

3/4” NPT

• Drain

3/4” NPT

INSTALLATION

When making a plumbing connection to the system,

remember to use a back-up wrench on the support

plumbing. Always use a good quality and approved

pipe sealant or Teflon tape on pipe threads.

Be careful not to get the pipe sealant inside the pipe

when making the connections. Do not over tighten the

connections.

It is recommended that plastic fittings be used when

connecting to the plastic connections of the system.

This will reduce the possibility of cracking the connec-

tions due to over tightening. If soldered plumbing is

used, do not apply heat to, or near, the filtration system.

The use of union (O-ring seal) connections is highly

recommended for ease of installation and future servic-

ing.

Suggested Tools and Supplies for

Installation

The following tools and supplies are suggested to make

the installation easier:

• Screwdriver

• Drill with bits

• Strap wrench

(up to 6” diameter)

• Tape measure

• Two gallon bucket

• Fresh 5 1/4% liq-

uid chlorine bleach

(such as Clorox®)

• Adjustable wrenches

• Pipe wrenches

• Level

• Pipe dope or Teflon

tape

Advertising