D. GAS BURNER ASSEMBLY

Gas-heated dryers are equipped with a

gas burner assembly consisting of four (4)

burner tubes, gas valve, HSI (Hot Surface

Ignition) ignitor, flame probe, sail switch,

and hi-limit thermostat. The inlet piping

enters through the rear of the dryer on

the left-hand side (viewing from the front)

and runs to the front of the dryer where

the gas valve is located.

E. DRIVE MOTOR

The T.E.F.C. (Totally Enclosed, Fan-Cooled)

drive motor is located approximately in the right

front hand corner of the dryer. It sits on an

adjustable base so that the motor can be easily

adjusted to the left or right. The drive motor is

a 3 HP motor and operates on 208 to 460 volts,

50/60 Hz, 3-phase (3ø).

F. BLOWER MOTOR and IMPELLOR

(GAS and STEAM)

The impellor is shaft driven. The blower motor drives the shaft

on which the impellor is mounted. This enables the impellor to

run at a higher RPM, thereby producing a higher airflow (CFM).