C. l.e.d. codes, Display codes – American Dryer Corp. Phase 6 Microprocessor Controls ML-190HS User Manual

Page 52

Advertising
background image

48

C. L.E.D. CODES

1. Display Codes

A

SLOPE FACTOR

ALL REV

ALWAYS REVERSING

ANTI WRINKL dELAY TIME

ANTI-WRINKLE DELAY TIME

ANTI WRINKL GUARd ACTIVE

ANTI-WRINKLE PROGRAM ACTIVE

ANTI WRINKL GUARd ON TIME

ANTI-WRINKLE GUARD ON TIME

AUTO CYCLE

AUTOMATIC MODE

b

HEAT LOSS (OFF SET) FACTOR

bURNER CONTROL FAIL

GAS ONLY ... POWER (24VAC) IS NOT EVIDENT AT GAS VALVE

bURNER FLAME FAIL

NO BURNER FLAME SENSED

bURNER SAFETY FAIL

GAS/ELECTRIC ONLY ... BURNER/OVEN OPEN HI-LIMIT CIRCUIT

bUZZ

BUZZER (TONE)

bUZZ TIME

BUZ TIME

ºCEL

DEGREE IN CELSIUS

CHECK MAIN FUSE

MAIN FUSE FAILURE

CLEAN LINT

PROMPT TO CLEAN LINT SCREEN, DRYER CYCLE LOCKOUT

COOL

COOL DOWN CYCLE IN PROGRESS

COOL TIME__M

COOL DOWN TIME

COOL TEMP___

COOL DOWN TEMPERATURE

CYCLEA

PREPROGRAMMED CYCLE A

CYCLEb

PREPROGRAMMED CYCLE B

CYCLEC

PREPROGRAMMED CYCLE C

CYCLEd

PREPROGRAMMED CYCLE D

CYCLEE

PREPROGRAMMED CYCLE E

CYCLEF

PREPROGRAMMED CYCLE F

dONE

DRYING or COOLING CYCLE COMPLETE OR DRYER IN ANTI-WRINKLE MODE

dRYING

DRYING CYCLE IN PROGRESS

dRY LEVEL___

DRYNESS LEVEL (PERCENTAGE OF EXTRACTION) (NUMERICAL VALUE)

dRY TEMP F___

DRYING TEMPERATURE

dRY TIME__M

LENGTH OF DRYING CYCLE

dRUM SAFETY FAIL

TUMBLER (BASKET) HI-LIMIT CIRCUIT IS OPEN

ELAPSE TIME___MIN

CYCLE DISPLAY TIME

ELECTRIC

SPECIFIC HEAT TYPE OF DRYER ... ELECTRICALLY HEATED

F

FABRIC TEMPERATURE

ºFAR

DEGREE IN FAHRENHEIT

FLASH

FLASH DISPLAY ACTIVE

GAS

SPECIFIC HEAT TYPE OF DRYER ... GAS HEATED

HOT

INDICATES AN OVERHEAT CONDITION

LINT dOOR

LINT DRAWER / DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. SWITCH CIRCUIT

LINT COUNT

DRYING CYCLES RANGE FROM 1-10 CYCLES BEFORE CLEAN LINT DISPLAY

__M REMAIN

CYCLE DISPLAY TIME

MAIN dOOR

DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. DOOR SWITCH CIRCUIT

MANUAL CYCLE

MANUAL MODE

MAX ANTI WRINKL GUARd

MAXIMUM GUARD TIME

NFLASH

FLASH DISPLAY NOT ACTIVE

NoAIR FLOW

SAIL SWITCH OPEN

NoANTI WRINKL GUARd

ANTI-WRINKLE PROGRAM IS NOT ACTIVE

NoBUZZ

NO BUZZER (TONE)

NoHEAT

GAS ONLY ... IGNITION ATTEMPT FAILURE

NoREV

NO REVERSE

No ROTATE SENSOR

NO ROTATIONAL SENSOR SELECTED

PROGRM

PROGRAM MODE

REAdY

NO CYCLE IN PROGRESS

ROTATE SENSOR ACTIVE

ROTATIONAL SENSOR SELECTED

ROTATE SENSOR FAIL

ROTATIONAL SENSOR CIRCUIT FAILURE

__RPM

MONITORS TUMBLER (BASKET) RPM WITH ROTATIONAL SENSOR CIRCUIT ACTIVE

SAIL SWITCH FAIL

GAS/ELECTRIC ONLY. ATTEMPT MADE TO START DRYER WITH SAIL SWITCH
DISABLED IN CLOSED POSITION

SELREV.

SELECT REVERSE

SPIN TIME

SPIN TIME

START GUARd

START ANTI WRINKLE GUARD CYCLE

STEAM

SPECIFIC HEAT TYPE OF DRYER ... STEAM HEATED

STOP TIME

STOP TIME

TEMP SENSOR FAIL CHECK

FAULT IN M.P. HEAT SENSING CIRCUIT

TEMP SENSOR FUSE