C. thermostats – American Dryer Corp. Phase 6 Microprocessor Controls ML-190HS User Manual

Page 25

Advertising
background image

21

To Replace Burner Tubes

1. Refer to “Replace Gas Valve” and

follow Step #1 through Step #6.

2. Remove four (4) screws securing

manifold rest and remove rest.

3. Remove the screws securing the

front flanges of the burner tubes

to the burner tube rest.

4. Remove the screws securing the

burner tube rest to the oven and

remove this rest.

5. Remove screws securing the burner box cover plate to the oven and remove this plate.

6. Remove burner tubes by sliding them out.

7. Replace by reversing procedure.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution.

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

To Replace HSI (Hot Surface Ignition) Module

1. Discontinue electrical power to the dryer.

2. Remove the wires connected to the

terminal strip at the bottom of the module.

3. Remove the two (2) pal nuts securing the

module to the mounting bracket.

4. Replace module by reversing procedure.

5. Reestablish electrical power to the dryer.

C. THERMOSTATS

To Replace Burner Hi-Limit Thermostat (Gas Models Only)

This thermostat is an important safety device serving as an added protection against failure of the airflow (sail

switch) to open in the event of motor failure or reduced airflow condition.