Deluxe food warmer, Operation – Antunes, AJ Series 9100100 User Manual

Page 11

Advertising
background image

DELUXE FOOD WARMER

10

P/N 1010678 Rev. F 09/04

DELUXE FOOD WARMER

11

P/N 1010678 Rev. F 09/04

OPERATION

General Information

ALL MODELS
When the operate button (Figure 5) is pressed and

released, power is supplied to the water pump (Water

Tank models) or solenoid valve (Direct Water Hookup

models). The pump/solenoid operates and water

sprays onto the heated steam generator (Figure 9).

The water flashes immediately into steam and steams

the product.

TIMER MODELS - DFW/DFWT/DFWF–150/250

EXCEPT DFWF-250 WITH MFG. NO 9100147
On Timer Models, one of two operational modes can

be used: Single Shot or Timed Cycle
Single Shot
The Operate Button (Figure 5) is pressed and released

to initiate a single steam shot. The Control Board

applies power to the Water Pump/Solenoid and a “shot”

of steam occurs.
Timed Cycle
The control is used to set the desired steamtime (up

to 99 minutes, 59 seconds). When the Start/Stop

Button (Figure 5) is pressed, the Control Board applies

power to the water pump/solenoid at regular intervals

for the duration of the displayed cycle time. The dis-

play counts down to zero when the cycle is complete,

sounds an audible signal, and then reverts back to the

original programmed cycle time. The unit is ready for

the next cycle when the green ready light is on.
IMPORTANT: Timer Models are factory programmed

for the following recommended settings:

• Total Cycle Time = [15.00] (15 minutes)

(Range: 3 sec. to 99 mins 59 secs)

• Shot Interval Time (SHO) = [00:20] (20 seconds)

(Range: 3 secs to 5 mins 59 secs). 20 seconds is

recommended.

• Water Volume (H

2

O) =

DFW/DFWT/DFWF-250 - [0_50]

DFW/DFWT-150 - [0_80]

(Range: 0.10 seconds to 2.50)

The above settings convert approximately 3/4 oz. (25

milliliters) of water into to steam every 20 seconds for

15 minutes. To change any of these settings see the

appropriate Operating Instructions for your specific unit.

Operating Instructions For (Non-Timer)

Models

1. Turn the Rocker Switch (power On/Off) to ON

(Figure 5).

2. Allow the unit to preheat for approximately 30

minutes.

NOTE: Do not push the operate button during

warm-up.

3. Open the Top Cover and place the product to be

steamed onto the Trivet, then close the Cover.

4. Press the operate button for 1 second then

release and wait 20 seconds for the steam to

penetrate the product. Repeat if product requires

more steam (see the Steaming Guide section of

this manual).

NOTE: Pressing and holding the operate button for

longer than 1 second at a time, and/or too often

(before 20 seconds), will flood out the generator

surface (Figure 9) and result in poor steaming.

5. Remove steamed product.
6. See the Steaming Guide section of this manual.

WARNING

To avoid injury, be careful when opening top

cover. Be sure to allow steam to escape before

putting hands or face over the steamer.

Advertising