TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-

ment should be performed by qualified service personnel. The unit should be unplugged when servicing,

except when electrical tests are required.

If the troubleshooting steps listed do not solve your machine problem, contact a Roundup Authorized

Service Agency for further assistance or service.

Problem

Possible Cause

Corrective Action

Control Display is blank

(Rocker Switch is ON but indica-

tor light is off)

Timer Models Only.

The power cord is not correctly plugged

in.

Plug the power cord into the appro-

priate outlet.

The power cord and/or electrical plug is

damaged.

Inspect electrical wire, plug, and

receptacle.

The main electrical panel circuit breaker

is off or has tripped.

Reset circuit breaker. Contact your

maintenance person or Authorized

Service Agency if it trips again.

Rocker Switch (power On/Off) is inoper-

able.

Contact your maintenance person

or Authorized Service Agency for

service.

Control Display is blank

(Rocker Switch is ON and indica-

tor light is on).

Timer Models Only

Control Board is inoperable.

Contact your maintenance person

or Authorized Service Agency for

service.

Transformer is inoperable.
Loose, burnt, or broken wires in circuit.

Unit does not heat up (Rocker

Switch is ON and indicator light

is on).

Hi-Limit Thermostat is tripped or inoper-

able.

Reset the Hi-Limit Thermostat

according to the Operations sec-

tion of this manual. If the Hi-Limit

Thermostat requires continuous

resetting, contact your Authorized

Service Agency for service.

Transformer is inoperable.
Solid State Relay is inoperable
Thermocouple is inoperable (Timer

Models Only).
Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in circuit.
Thermistor is inoperable (Non-Timer

Models Only).

The unit’s main electrical panel

circuit breakers trips.

Damaged receptacle, plug, or cord or a

loose connection or an internal compo-

nent failure.

Turn the unit off, allow it to cool to

room temperature, and then restart

the unit. Contact your maintenance

person or Authorized Service Agency

if the condition repeats.

Circuit breaker is overloaded.

Water leaking inside electrical

housing.

Pinhole leak in robber hoses (DFW/

DFWT-100/150).

Replace hoses.

Loose or damaged water line tubes and/

or fittings inside electrical housing.

Tighten or replace tubes and/or fit-

tings.

Water leaking at Male Quick

Disconnect fitting while it is

engaged into steamer (DFW/

DFWT/DFWF-200/250)

The O-ring on the Male Quick

Disconnect is damaged.

Replace O-ring. Refer to the

Maintenance section of this manual

(Figure 12).