5. Replace damaged or worn parts as needed.
6. Verify that the Water Pressure Regulator is set to

20-25 PSI (1.4-1.7 kg/cm2 or 138-172 kPa).

TOP COVER ADJUSTMENT
It is normal for a small amount of steam to escape

around the front and sides of the Top Cover. However,

excessive steam may indicate the Top Cover Gasket is

worn and/or the cover is out of adjustment or damaged.

1. With the Top Cover closed, loosen the four (4)

rear hinge bracket screws (Figure 12) one turn

only.

2. Push down on the top cover heavily (Figure

12). This ensures the gasket is seated squarely

around the generator. While maintaining the

downward pressure, re-tighten the screws.

Press firmly On the

Top Cover

Figure 12. Top Cover Adjustment