HKV 084 Blower Performance

Blower Performance

All Data is Wet Coil

Airflow

(SCFM)

ESP

Airflow (cfm) at External Static Pressure (in. wg)

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

1.10

1.20

1.30

1.40

1.50

2100

BHP

0.24

0.29

0.34

0.37

0.41

0.44

0.49

0.54

0.59

0.64

0.69

0.74

0.79

0.84

2100

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

C

C

C

C

2100

RPM

410

457

499

537

577

612

647

678

710

737

764

791

815

838

2100

Turns Open

5

3.5

4.5

6

5

4

3

2.5

1.5

6

5.5

4.5

4

3

2200

BHP

0.28

0.315

0.34

0.39

0.44

0.49

0.54

0.59

0.64

0.69

0.74

0.79

0.84

0.9

2200

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

C

C

C

C

2200

RPM

424

467

507

548

584

621

653

684

716

743

772

797

821

847

2200

Turns Open

4.5

3.5

4.5

5.5

5

4

3

2

1.5

6

5

4.5

3.5

3

2300

BHP

0.29

0.34

0.39

0.44

0.49

0.54

0.59

0.64

0.69

0.74

0.79

0.84

0.89

0.94

2300

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

C

C

C

C

2300

RPM

435

476

518

555

590

627

659

692

721

751

777

803

829

853

2300

Turns Open

4.5

3

4

5.5

4.5

3.5

2.5

2

1.5

5.5

5

4

3.5

2.5

2400

BHP

0.29

0.34

0.39

0.44

0.49

0.54

0.59

0.64

0.69

0.74

0.79

0.84

0.89

0.94

0.99

2400

Sheave/Mtr

B

B

B

A

A

A

A

A

A

A

C

C

C

C

C

2400

RPM

403

446

485

527

563

600

633

665

697

726

756

783

811

835

858

2400

Turns Open

5

4

3

6

5.5

4.5

3.5

2.5

1.5

1

5.5

4.5

4

3

2.5

2500

BHP

0.31

0.34

0.39

0.44

0.49

0.54

0.59

0.64

0.74

0.79

0.84

0.89

0.94

0.99

1.04

2500

Sheave/Mtr

B

B

B

A

A

A

A

A

A

A

C

C

C

C

E

2500

RPM

411

452

495

532

567

604

636

670

700

729

759

786

813

838

864

2500

Turns Open

5

4

2.5

6

5.5

4

3.5

2.5

1.5

1

5.5

4.5

3.5

3

2.5

2600

BHP

0.34

0.43

0.48

0.53

0.58

0.63

0.68

0.73

0.78

0.83

0.88

0.93

1.03

1.08

1.13

2600

Sheave/Mtr

B

B

B

A

A

A

A

A

A

A

C

C

E

E

E

2600

RPM

420

460

500

536

570

606

638

671

701

729

759

786

814

839

865

2600

Turns Open

4.5

3.5

2.5

6

5

4

3

2

1.5

1

5

4

4

3

2.5

2700

BHP

0.38

0.43

0.48

0.53

0.59

0.64

0.69

0.74

0.79

0.84

0.89

0.94

1.04

1.09

1.14

2700

Sheave/Mtr

B

B

B

A

A

A

A

A

A

A

C

C

E

E

E

2700

RPM

423

463

504

539

576

609

641

674

703

734

762

788

816

841

867

2700

Turns Open

4.5

3.5

2

5.5

5

4

3

2

1.5

1

5

4

4

3

2.5

2800

BHP

0.39

0.44

0.49

0.54

0.64

0.69

0.74

0.79

0.84

0.89

0.94

1.04

1.09

1.12

1.22

2800

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

C

E

E

E

E

2800

RPM

431

474

510

545

581

613

647

677

706

737

764

793

818

843

869

2800

Turns Open

4.5

3

2

5.5

5

4

3

2

1.5

5.5

1

4.5

4

3

2.5

2900

BHP

0.44

0.49

0.54

0.59

0.64

0.74

0.79

0.84

0.89

0.94

1.04

1.09

1.14

1.19

1.24

2900

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

E

E

E

E

E

2900

RPM

440

481

517

551

586

618

651

681

710

740

767

795

821

845

872

2900

Turns Open

4

3

2

5.5

4.5

3.5

2.5

1.5

1

5.5

5.5

4.5

3.5

3

2

3000

BHP

0.43

0.49

0.54

0.59

0.64

0.69

0.74

0.84

0.89

0.94

1.04

1.09

1.14

1.19

1.24

1.29

3000

Sheave/Mtr

B

B

B

A

A

A

A

A

A

A

D

E

E

E

E

E

3000

RPM

412

455

492

526

563

595

628

658

687

718

745

774

800

826

852

876

3000

Turns Open

5

3.5

2.5

6

5.5

4.5

3.5

2.5

1.5

1.5

1

5

4.5

3.5

3

2

3100

BHP

0.44

0.53

0.59

0.64

0.69

0.74

0.84

0.89

0.94

0.99

1.04

1.14

1.19

1.24

1.34

1.39

3100

Sheave/Mtr

B

B

B

A

A

A

A

A

A

A

D

E

E

E

E

E

3100

RPM

421

459

499

533

569

600

633

663

691

722

749

777

803

828

854

878

3100

Turns Open

4.5

3.5

2.5

6

5

4

3

2

1.5

1.5

1

5

4

3.5

2.5

2

3200

BHP

0.49

0.54

0.64

0.69

0.74

0.84

0.89

0.94

0.99

1.04

1.14

1.19

1.24

1.34

1.39

1.44

3200

Sheave/Mtr

B

B

B

A

A

A

A

A

A

D

E

E

E

E

E

E

3200

RPM

441

478

513

549

581

614

644

672

703

730

759

785

810

837

861

887

3200

Turns Open

4

3

2

5.5

5

4

3

2

1.5

1.5

5.5

4.5

4

3

2.5

2

3300

BHP

0.54

0.64

0.69

0.74

0.83

0.89

0.94

0.99

1.04

1.14

1.23

1.29

1.34

1.44

1.49

3300

Sheave/Mtr

B

B

A

A

A

A

A

A

D

D

E

E

E

E

E

3300

RPM

456

495

529

561

595

625

656

685

712

741

767

795

820

844

870

3300

Turns Open

3.5

2.5

6

5

4.5

3.5

2.5

2

1.5

1

5

4.5

3.5

3

2.5

3400

BHP

0.63

0.69

0.74

0.79

0.84

0.94

0.99

1.04

1.14

1.19

1.24

1.34

1.44

1.49

3400

Sheave/Mtr

B

B

A

A

A

A

A

D

1.5

D

E

E

E

E

3400

RPM

471

506

539

574

604

633

664

692

721

747

773

800

825

851

3400

Turns Open

3

2

5.5

5

4

3.5

2.5

2

1.5

1

5

4

3.5

2.5

3500

BHP

0.64

0.74

0.79

0.84

0.94

0.99

1.04

1.14

1.23

1.29

1.34

1.44

1.49

3500

Sheave/Mtr

B

A

A

A

A

A

D

D

D

E

E

E

E

3500

RPM

486

520

555

586

615

647

674

704

730

756

784

808

835

3500

Turns Open

2.5

6

5.5

4.5

4

3

2.5

1.5

1

5.5

4.5

4

3

A = Standard Static/Standard Motor, B = Low Static/Standard Motor, C = High Static/Standard Motor, D = Standard Static/Large Motor, E = High Static/Large Motor
Unit factory shipped with standard static sheave and drive at 2.5 turns open. Other speed require field selection.
For applications requiring higher static pressures, contact your local representative. Performance data does not include drive losses and is based on sea level conditions.
Do not operate in black regions. All airflow in rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.