Blower Performance

HKV 300 Blower Performance

10600

BHP

3.68

3.88

4.08

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

5.88

6.18

6.38

6.58

6.78

10600

Sheave/Mtr

B

B

B

B

A

A

A

D

D

D

D

E

E

E

E

E

10600

RPM

680

709

737

763

790

817

842

867

889

912

935

957

979

1000

1021

1042

10600

Turns Open

4.5

3.5

3

2

5.5

4.5

4

3

2.5

2

1

3

2.5

2

1.5

1

10800

BHP

3.88

4.08

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

5.88

6.18

6.38

6.58

6.78

6.98

10800

Sheave/Mtr

B

B

B

A

A

A

D

D

D

D

E

E

E

E

E

E

10800

RPM

691

717

745

772

799

825

850

873

897

920

943

965

986

1006

1026

1047

10800

Turns Open

4.5

3.5

2.5

6

5

4.5

3.5

3

2

1.5

3.5

3

2.5

2

1.5

1

11000

BHP

4.08

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

6.18

6.28

6.48

6.68

6.88

7.08

7.38

11000

Sheave/Mtr

B

B

B

A

A

D

D

D

D

D

E

E

E

E

E

E

11000

RPM

704

729

756

783

810

836

859

883

907

929

952

972

993

1014

1035

1055

11000

Turns Open

3.5

3

2

5.5

5

4

3

2.5

2

1.5

3.5

3

2.5

2

1

0.5

11200

BHP

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

6.00

6.28

6.48

6.68

6.88

7.08

7.38

11200

Sheave/Mtr

B

B

A

A

D

D

D

D

D

D

E

E

E

E

E

11200

RPM

714

740

767

794

818

844

868

892

916

938

959

981

1002

1023

1043

11200

Turns Open

3.5

2.5

6

5.5

4.5

3.5

3

2.5

1.5

1

3

2.5

2

1.5

1

11400

BHP

4.48

4.68

4.88

5.08

5.28

5.48

5.78

6.08

6.28

6.48

6.68

6.88

7.18

7.48

11400

Sheave/Mtr

B

B

A

D

D

D

D

D

D

D

E

E

E

E

11400

RPM

726

752

779

803

829

854

878

902

925

948

970

990

1011

1031

11400

Turns Open

3

2

5.5

5

4.5

3.5

3

2

1.5

1

3

2.5

2

1.5

11600

BHP

4.68

4.88

5.08

5.28

5.48

5.68

6.00

6.28

6.48

6.68

6.88

7.18

7.48

11600

Sheave/Mtr

B

A

D

D

D

D

D

D

D

E

E

E

E

11600

RPM

738

763

788

813

839

864

888

911

934

955

977

998

1019

11600

Turns Open

2.5

6

5.5

4.5

4

3

2.5

2

1

3.5

2.5

2

1.5

11800

BHP

4.88

5.08

5.28

5.48

5.78

6.08

6.28

6.48

6.68

6.98

7.28

7.48

11800

Sheave/Mtr

B

D

D

D

D

D

D

D

D

E

E

E

11800

RPM

750

775

799

824

849

874

898

921

944

964

986

1007

11800

Turns Open

2

5.5

5

4

3.5

3

2.5

2

1

3

2.5

2

12000

BHP

5.08

5.28

5.48

5.78

6.08

6.28

6.48

6.68

6.98

7.28

7.48

12000

Sheave/Mtr

D

D

D

D

D

D

D

D

E

E

E

12000

RPM

758

783

808

833

858

880

904

927

950

972

993

12000

Turns Open

6

5.5

4.5

4

3.5

2.5

2

1.5

3.5

3

2.5

12200

BHP

5.28

5.48

5.78

6.08

6.28

6.48

6.68

6.98

7.28

7.48

12200

Sheave/Mtr

D

D

D

D

D

D

D

D

E

E

12200

RPM

769

794

819

843

866

890

913

936

958

980

12200

Turns Open

6

5

4.5

4

3

2.5

2

1.5

3

2.5

12400

BHP

5.68

5.88

6.08

6.28

6.48

6.78

7.08

7.28

7.48

12400

Sheave/Mtr

D

D

D

D

D

D

D

D

E

12400

RPM

781

815

830

854

878

900

923

946

968

12400

Turns Open

5.5

4.5

4.5

3.5

3

2

1.5

1

3

12600

BHP

5.88

6.08

6.28

6.58

6.88

7.08

7.28

12600

Sheave/Mtr

D

D

D

D

D

D

D

12600

RPM

793

817

841

863

886

910

933

12600

Turns Open

5

4.5

4

3

2.5

2

1.5

A = Standard Static/Standard Motor, B = Low Static/Standard Motor, C = High Static/Standard Motor, D = Standard Static/Large Motor, E = High Static/Large Motor
Unit factory shipped with standard static sheave and drive at 2.5 turns open. Other speed require field selection.
For applications requiring higher static pressures, contact your local representative. Performance data does not include drive losses and is based on sea level conditions.
Do not operate in black regions. All airflow in rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.

All Data is Wet Coil

Table Continued from Previous Page

Advertising