Communicating with the R325PE

Step 1: Move all dipswitches to the OFF position. Place jumper on Pins 1 & 2.

Inage 6.3

1. Connect P1 to PC via RS485-232 Converter Card or USB485 Converter Card.

2. Set up HyperTerminal by selecting correct COM port

3. Settings for HyperTerminal is as follows: 57600, 8 bits, None, 1, None

4. The R325P Driver only version allows for changing the hold timeout settings, the amount of mixed

decay, and to check the firmware revision level.

RS485-232 Converter Card

Figure 6.2

Move ALL

dipswitches

to the OFF

Position

Jumper is

placed

closest to

the LED.