Query commands – RMS Technologies R325P DRIVER User Manual

Page 21

Advertising
background image

Command

(Case

Sensitive)

Operand

Example

Description

QUERY COMMANDS

FR -

#AFR

Firmware Revision - Query Only

- Returns 3 digit part code followed by 3 digit firmware

revision value.

Reply

*AFR325PEV100 //R325PE firmware revision 1.00

MA 65 - 90

#AMA88

Sets the unit

address to 88

(‘X’)

My Address - Command or Query

Default = 65

- Reads or sets the unit address. The value read or entered

is the decimal value of the ASCII character designated as

the unit address. (65 = ‘A’ and 90 = ‘Z’)

The change to a new address is immediate, in that the

command response will use the new address

RS 0-1023

#ARS

Reads the

switch inputs

Read Switches - Query Only

- Reads the TRUE (1) or FALSE (0) state of the three

optically coupled inputs, combined into a single three-bit

value. This command is used to check the correct

operation of this interface. - The value order of the inputs

is ‘Direction’, ‘Disable’, and ‘Step’; in descending order.

‘Direction’ has the value 4 (100)

‘Disable’ has the value 2 (010)

‘Step’ has the value 1 (001)

TI -

#ATI

Reads the

switch inputs

Test Inputs - Query Only

Step, Direction, and Disable all return a value in decimal

form.

The value order of the inputs is:

‘Direction’, ‘Disable’, and ‘Step’; in descending order.

‘Direction’ has the value 4 (100)

‘Disable’ has the value 2 (010)

‘Step’ has the value 1 (001)

Reply

*ATI3 // 3 = ‘011’

BR 9600 – 57600 #ABR9600

Sets the Baud

Rate to 9600

bps

Baud Rate – Query and Command

Sets or reads the baud rate.

RMS Technologies

Page 21

Version 1.01

R325PE Single Axis Closed loop Driver/Indexer Manual

5/29/2013