9. Troubleshooting

R325P is not functioning correctly

Try putting the R325P into TEST mode by placing a jumper on Pins 3 & 4 of J1 as shown below. The motor

should twitch back and forth slightly if the R325P is functioning properly.

R325P not moving the motor (Step/Dip)

Verify that the 5V is being supplied to Pin 1.

The R325P is causing the motor to vibrate and jitter back and forth

Are the Motor phases switched? Be sure to check that motor wires are connected to Pins 6 through 9, in the

order of A, A Bar, B, B Bar. To check which wires belong to one phase, take a Meter to measure resistance

between any two wires. If there is a finite value between two of them, insert the wires into pins 6 and 7, OR

pins 8 and 9. Insert the remaining two wires accordingly.

Technical Support

By Telephone: 408-919-0200

(Monday-Friday; 8:00 AM - 5:00PM Pacific)

On the Web: www.linengineering.com

Our technical support group is glad to work with you in answering your questions. If you cannot find the solution

to your particular application, or, if for any reason you need additional technical assistance, please call technical

support at 408-919-0200.