7. COMMAND TABLES

The R325PE can also be used as an indexer with closed loop controls. Basic controller commands can be used

but users cannot store programs to the unit. This unit is commonly used with a user-created GUI or PLC’s that

can communicate commands via ASCII and serial port.

Basic Configuration Commands

Function

Query/Command

Code

Value

Minimum

Maximum Default

Load Defaults

N

LD

None

-

-

-

Save Data

N

SD

None

-

-

-

Module Address

Q/C

MA

Numeric 65 (A)

90 (Z)

65 (A)

Baud Rate

Q/C

BR

Numeric 9600

57600

9600

Table 7.1

Axis Configuration Commands

Function

Query/Command

Code

Value

Minimum

Maximum Default

Acceleration

Q/C

AC

Numeric 1

250

10

Hold Current

Q/C

HI

Numeric 0

3000

300

Hold Timeout

Q/C

HT

Numeric 100

5000

500

Min. Velocity

Q/C

MV

Numeric 250

15,000

250

Percent Fast Decay Q/C

PF

Numeric 0

3

2

Run Current

Q/C

RI

Binary

300

3000

1000

Read Switches

Q

RS

Numeric 0

1023

-

Step Resolution

Q/C

SR

Numeric 1

256

8

Start Velocity

Q/C

SV

Numeric 250

15,000

1000

Velocity Limit

Q/C

VL

Numeric 250

50,000

15,000

Zero Position

C

ZP

None

-

-

-

Table 7.2

RMS Technologies

Page 13

Version 1.01

R325PE Single Axis Closed loop Driver/Indexer Manual

5/29/2013