10 vp-725na communication protocol, Vp-725na communication protocol – Kramer Electronics VP-725NA User Manual

Page 59

Advertising
background image

54

VP-725NA - VP-725NA Communication Protocol

10 VP-725NA Communication Protocol

Communication Confirmation:

Send:

CR

Reply:

CR>

Set and Get command:

Set Command: YControl_TypeFunctionParamCR

Reply: ZControl_TypeFunctionParamCR>

Get Command: YControl_TypeFunctionCR

Reply: ZControl_TypeFunctionParamCR>

Example 1 (select VGA1 as video input channel):

"Y01570CR"
"Z01570CR>"

Example 2 (get selected current input channel):

"Y 1157CR"
"Z 11570CR>" (0 = VGA 1)

Definition:

: ASCII Code 0x20

CR: ASCII Code 0x0D

After a set type Command setting, system responds with a string “Done”.

The default data rate is 9600 Baud, with no parity, 8 data bits and 1 stop bit.