The card should be filled out with circuit information for each of the circuit breakers installed in
the panel and inserted in the card holder. The card holder has a pressure sensitive adhesive
backing for attachment.

Figure 4. Circuit Breaker Designation Card

1.17 Voltage Designation Label

A voltage designation label such as shown in

Figure 5

is provided with the circuit breaker panel.

The label is intended to be filled out with the actual voltage present on the buses and placed on
the panel. The voltage designation label has a pressure sensitive adhesive backing for
attachment.

Figure 5. Voltage Designation Label

1.18 Material and Finish

The panel chassis and brackets are made of 16-gauge cold rolled steel. The panel and brackets
are finished with a putty-color powder coat.

1.19 Cooling

The circuit breaker panel is ventilated to allow efficient convection cooling of all components
without the use of fans or blowers. Holes are provided in the top and bottom of the panel to allow
heated air to escape from the panel and cool air to enter.