3 start-up and power-down procedure, Ata6264 [preliminary – Atmel ATA6264 User Manual

Page 14

Advertising
background image

14

4929B–AUTO–01/07

ATA6264 [Preliminary]

5.3

Start-up and Power-down Procedure

The ATA6264 is powered via the pin K30 (battery voltage) and via a diode or a resistor it is con-
nected to the ignition key line K15. In order to detect an interruption on one of these pins
correctly, resistors are implemented at these pins. Normally, the main supply pin of ATA6264 is
pin K30. In the case of a missing or a too-low voltage at pin K30, the whole IC is supplied from
the backup power supply capacitor hooked up to pin EVZ.

Figure 5-3.

Block Diagram Start-up and Power-down Procedure

VCP

VCP

K30

EVZ

VEVZ

V

VSAT

V

VPERI

Comp

VEVZ

K15GOOD

V

K15

= 3V to 4.15V

(40 mV to 175mV Hysteresis)

Serial interface

(KEY - LATCH)

VSAT

VCP

Comp

CORE_EN

V

PERI

= 1.25V to 1.7V

(50 mV to 150 mV Hysteresis)

Comp

VSATGOOD

V

SAT

= 6.77V to 7.2V

(200 mV to 500 mV Hysteresis)

Comp

V

EVZ

V

CP

K15

K30

CP

GEVZ

EVZEN

CORESWAP

5V

IREF lost

signal

V

K30

= 3.85V to 5V

(50 mV to 150 mV Hysteresis)

Power

sequencing

VSAT
driver

SVSAT

EVZ

V

VCORE

VCORE

SVCORE

VK30

IP

VEVZ

driver

Comp

K30GOOD

VCORE

driver

VCore

driver

VPERI

driver

VPERI

SVPER

IP

V

K30

= 6.1V to 8.1V (ON)

(0.5V to 1V Hysteresis)

Comp

EVZGOOD

V

EVZ

= 7.5V to 9V (ON)

V

EVZ

= 5.5V to 6.2V (OFF)

Advertising