Ata6264 [preliminary – Atmel ATA6264 User Manual

Page 51

Advertising
background image

51

4929B–AUTO–01/07

ATA6264 [Preliminary]

Configuration of watchdog trigger:

For the configuration of the watchdog prescaler, a special serial interface command is
necessary.

Note:

a, b, and c to be set as defined in

Table 16-1

The status of the watchdog prescaler is indicated in the status register.

Description

MSByte

LSByte

Hex Code

7

6

5

4

3

2

1

0

7

6

5

4

3

2

1

0

Configure prescaler

0

1

1

0

0

0

0

0

1

1

1

1

0

a

b

c

60Fx

Table 16-1.

Watchdog Prescaler Command

Selection Bits

Retrigger Time (ms)

a

b

c

0

0

0

Set to default (16 ms)

0

0

1

4

0

1

0

8

0

1

1

16

1

0

0

32

1

0

1

64

1

1

0

128

1

1

1

Set to default (16 ms)