2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,

clean, and static-protective surface. See the Rack Installation Instructions that comes with the server.

3. Remove the server cover. See “Removing the server cover” on page 75.

4. Disconnect the cable from the ThinkServer RAID Super Capacitor Module and then remove the two

screws that secure the ThinkServer RAID Super Capacitor Module bracket. Then, hold the bracket with
the ThinkServer RAID Super Capacitor Module and lift it up.

ID

Mem

CPU

PSU

Figure 106. Removing the ThinkServer RAID Super Capacitor Module with the bracket

5. Gently press the tab

1

on the bracket and remove the ThinkServer RAID Super Capacitor Module from

the bracket at the same time.

Figure 107. Removing the ThinkServer RAID Super Capacitor Module from the bracket

6. Touch the static-protective package that contains the new ThinkServer RAID Super Capacitor Module

to any unpainted surface on the outside of the server. Then, take the new ThinkServer RAID Super
Capacitor Module out of the package.