AOC P/N : 41A50-144 User Manual

Page 20

Advertising
background image

19

POWER-BLOCK check
*

*Note : the Waveform of U304 pin 2 can determined the power situation

1. stable rectangle waveform with equal duty, freq around 150K-158KHz

that means all power of this interface board is in normal operation
,and all status of 5V & 3.3V is working well

2. unstable or uneven rectangle waveform without same duty, that means ABNORMAL operation was

happened, check 3.3V or 5V ,if short-circuit or bad component

3. rectangle waveform with large spike & harmonic pulse on front side , means all 3.3v is no load, U200

Gmzan1 was shut-down, and only U302 MCU still working , that means the monitor is in power saving
status , all power system is working well .




























OK

Check U304 pin 2 is a stable rectangle wave?
Around 150k-158kHz stable rectangle wave
with equal duty without any spike or harmonic
pulse?

OK

NG, with
harmonic
pulse

Check U304 pin 2 is a unstable rectangle wave ?

The interface board power is good

Measure input power at U304 LM2596 pin 1=
12V ?

Check ADAPTER and connector if

loose?

NG

NG

Check all 3.3V & 5V power, there is
short circuit or bad component was
happened

OK, unstable wave

The interface board is in power-
saving state, press power key to wake
up & check your signal input

Advertising