There is an interferences in

DOS MODE

NOTE :the criteria of doing AUTO-CONFIGURATION : must be a full-size screen, if the screen not full , the auto-
configuration will fail. So in dos mode ,just set your “CLOCK” in OSD-MENU to zero or use some EDITOR
software which can full fill the whole screen (ex: PE2, HE) and then press “AUTO”
Or you can use “DOS1.EXE” which attached in your Driver disk to optimize DOS mode performance

V. THE PANEL LUMINANCE WAS DOWN


Use white pattern and resolution 1280x1024 @ 60Hz , CHROMA 7120 measured the center of panel


Set Contrast, brightness =maximal, RGB= 50
Quit from OSD-screen, measured Y(luminance)
With chroma 7120, check Y= 240±10 CD/M2 ?

Adjust VR201 until maximal, measured Y =
240±10 cd/m2 ?

NG

NG

If the Y less than 160 cd/m2 (after the VR201=
MAX, contrast, brightness = max) then change the
LAMP of panel

If Y can reach

190 cd/m2 that means

The lamp still working well, so we just re-do the
white-balance process
As following procedure

OK

Use white-pattern, press MENU button along
with AC power-plug in ( you will in factory
mode) The OSD-menu will be at left-top of
screen,

press AUTO button to automatically adjust
blacklevel value, you will see the sign PASS ,if
FAIL , manual adjust the blacklevel until value 43 !

Set contrast, brightness to max, and turn the VR201
to max , wait for 20 minutes until the luminance Y
stable
The Y should be larger than 200 cd/m2
(for panel which already use for a year, the Y
luminance might be a little down, around 180
cd/m2, there is acceptable too)

Follow this manual page 7 item 4-2 method to
more detail procedure for do a white-balance
adjust

OK