The SCLK frequency (1/SCLK period) can be set to the range of 10-to-135 MHz. Using the DDS (direct digital
synthesis) technology the clock recovery circuit can generate any SCLK clock frequency within this range.

The pixel clock (DCLK or destination clock) is used to drive a panel when the panel clock is different from SCLK (or
SCLK/2). It is generated by a circuit virtually identical to the clock recovery circuit. The difference is that DCLK is
locked to SCLK while SCLK is locked to the Hsync input. DCLK frequency divided by N is locked to SCLK
frequency divided by M. The value M and N are calculated and programmed in the register by firmware. The value M
should be close to the Source Htotal value.

Figure 4. Clock Recovery Circuit






































Sample

Phase

Delay

DDS Digital

Clock

Synthesis

Course

Adjust

Fine

Adjust

Analog

PLL & VCO

Clock

Divider

÷ n

PLL

Divider

÷ m

Prescaler

÷ 2 (or 1)

Source

Horizontal

Total Divider

Hsync

DDS Output

VCO

Output

SCLK

Analog

PLL & VCO

Post Scale

÷ 2 (or 1)

PLL Divider

÷ n (2 to 8)

PLL Divider

÷ 2 (or 1)

RCLK

TCLK