background image

ToughRunners / ScanWear – Communication Protocol v1.2

- 33 -

Data Capture

for Workforce

in Motion

Command

Header

Length

Payload

Answer

Set sniff

0x09

00 04

[MSB of MinSniff interval, LSB of MinSniff

interval, MSB of MaxSniff interval, LSB of

MaxSnif interval]

0x09 00 01 01 if done

0x09 00 01 00 if not

Command

Header Length Payload

Answer

Set sniff

(advanced)

0x09

00 08

[MSB of MinSniff interval, LSB of MinSniff

interval, MSB of MaxSniff interval, LSB of

MaxSnif interval,

Sniff Attempts MSB, Sniff attempts LSB,

Sniff timeout MSB, Sniff timeout LSB]

0x09 00 01 01 if done

0x09 00 01 00 if not

(default 0xf0, 0x50, 0x08, 0x08)

Command

Header

Length

Payload

Answer

Get sniff

0x10

00 00

0x10 00 08 [MSB of MinSniff interval, LSB of MinSniff interval,

MSB of MaxSniff interval, LSB of MaxSnif interval, Sniff

Attempts MSB, Sniff attempts LSB, Sniff timeout MSB, Sniff

timeout LSB]

When setting only MinSniff and MaxSniff values, the default value 0x08 will be used for Sniff

attempts and Sniff timeout.

Typical values are:

Full speed (full power)

MinSniff = 0

MaxSniff = 0

Very Low Power (low speed): (sniff of 500ms Only are accepted. If the remote device does not

support sniffs of 500ms, no sniff will be used)

MinSniff = 0x0320

MaxSniff = 0x0320

Very Low Power (low speed): (sniff between 250ms to 500ms are accepted. No sniff will be used if

the remote device does not support any sniff values in this specified range)

MinSniff = 0x0160

MaxSniff = 0x0320

Low Power (medium speed):

Advertising