11

Clearing sFlow statistics

To clear the UDP packet and sFlow sample counters in the show sflow display, enter the following
command.

Brocade#clear statistics

Syntax: clear statistics

This command clears the values in the following fields of the show sflow display:

UDP packets exported

sFlow samples collected

NOTE

This command also clears the statistics counters used by other features.

The maximum sFlow sample size

The maximum size of a flow sample sent to the sFlow collector.

exporting cpu-traffic

Indicates whether or not the sFlow agent is configured to export data
destined to the CPU (e.g., Telnet sessions) to the sFlow collector:

enabled

disabled

exporting cpu-traffic sample rate

The sampling rate for CPU-directed data, which is the average ratio of
the number of incoming packets on an sFlow-enabled port, to the
number of flow samples taken from those packets.

exporting system-info

Indicates whether or not the sFlow agent is configured to export
information about CPU and memory usage to the sFlow collector:

enabled

disabled

exporting system-info polling interval

Specifies the interval, in seconds, that sFlow data is sent to the sFlow
collector.

UDP packets exported

The number of sFlow export packets the Brocade ICX 6650 device has
sent.
NOTE: Each UDP packet can contain multiple samples.

sFlow samples collected

The number of sampled packets that have been sent to the collectors.

sFlow ports

The ports on which you enabled sFlow.

Module Sampling Rates

The configured and actual sampling rates for each module. If a module
does not have any sFlow-enabled ports, the rates are listed as 0.

Port Sampling Rates

The configured and actual sampling rates for each sFlow-enabled port.
The Subsampling factor indicates how many times the sampling rate of
the port's module is multiplied to achieve the port's sampling rate.
Because of the way the actual sampling rates are computed, the
Subsampling factors are always whole numbers.

TABLE 56