Syslog messages for port flap dampening – Brocade Communications Systems Brocade ICX 6650 User Manual

Page 60

Advertising
background image

42

Brocade ICX 6650 Administration Guide

53-1002600-01

Basic port parameter configuration

2

Table 10

defines the port flap dampening statistics displayed by the show link-error-disable all

command.

Syntax: show link-error-disable [all]

Syslog messages for port flap dampening

The following Syslog messages are generated for port flap dampening.

If the threshold for the number of times that a port link toggles from “up” to “down” then
“down” to “up” has been exceeded, the following Syslog message is displayed.

0d00h02m10s:I:ERR_DISABLE: Link flaps on port ethernet 16 exceeded threshold;

port in err-disable state

If the wait time (port is down) expires and the port is brought up the following Syslog message
is displayed.

0d00h02m41s:I:ERR_DISABLE: Interface ethernet 16, err-disable recovery timeout

TABLE 10

Output of show link-error-disable

Column

Description

Port #

The port number.

Threshold

The number of times the port link state will go from up to down and
down to up before the wait period is activated.

Sampling-Time

The number of seconds during which the specified toggle threshold can
occur before the wait period is activated.

Shutoff-Time

The number of seconds the port will remain disabled (down) before it
becomes enabled. A zero (0) indicates that the port will stay down until
an administrative override occurs.

State

The port state can be one of the following:

Idle – The link is normal and no link state toggles have been
detected or sampled.

Down – The port is disabled because the number of sampled errors
exceeded the configured threshold.

Err – The port sampled one or more errors.

Counter

If the port state is Idle, this field displays N/A.

If the port state is Down, this field shows the remaining value of the
shutoff timer.

If the port state is Err, this field shows the number of errors
sampled.

Brocade# show link-error-disable all

Port -----------------Config--------------- ------Oper----

# Threshold Sampling-Time Shutoff-Time State Counter

------- --------- ------------- ------------ ----- -------

1/1/3 1 14 3 Idle N/A

1/1/32 2 20 Indefinite Idle N/A

1/1/56 1 10 Indefinite Down N/A

1/2/1 10 3 10 Idle N/A

1/3/4 4 10 2 Idle N/A

1/3/8 1 10 Indefinite Idle N/A

Advertising