Syslog messages

Table 57

lists all of the Syslog messages. Note that some of the messages apply only to Layer 3

Switches.

NOTE

This chapter does not list Syslog messages that can be displayed when a debug option is enabled.

The messages are listed by message level, in the following order, then by message type:

Emergencies (none)

Alerts

Critical

Errors

Warnings

Notifications

Informational

Debugging

TABLE 57

Brocade Syslog messages

Message level

Message

Explanation

Alert

<num-modules> modules and 1 power
supply, need more power supply!!

Indicates that the chassis needs more
power supplies to run the modules in the
chassis.
The <num-modules> parameter indicates
the number of modules in the chassis.

Alert

Fan <num>, <location>, failed

A fan has failed.
The <num> is the fan number.
The <location> describes where the failed
fan is in the chassis.

Alert

MAC Authentication failed for
<mac-address> on <portnum>

RADIUS authentication was successful for
the specified <mac-address> on the
specified <portnum>; however, the VLAN
returned in the RADIUS Access-Accept
message did not refer to a valid VLAN or
VLAN ID on the Brocade device. This is
treated as an authentication failure.

Alert

MAC Authentication failed for
<mac-address> on <portnum> (Invalid User)

RADIUS authentication failed for the
specified <mac-address> on the specified
<portnum> because the MAC address sent
to the RADIUS server was not found in the
RADIUS server users database.