Comm LED Operation

The Comm LED - located on the upper enclosure connector
panel - indicates system control status. This can be used
determine if the luminaire is receiving a control signal. LED
indications are as follows:

Green - The Comm LED will light green if either DMX
or Ethernet control is present. Note that if both valid
DMX and Ethernet control are being received, DMX
control will take precedence.

Red - The Comm LED will light red if no DMX or
Ethernet is present.

Bypassing Calibration

If the menu screen is touched (in the center) and held during startup, the
luminaire will present a menu that provides the option to bypass
calibration. This feature allows the luminaire to skip the calibration
sequence so that it can be powered up in the case for configuration
purposes.
To bypass calibration:
Step 1. Connect power to luminaire.
Step 2. At startup, touch center of menu screen and hold until Bypass

Calibration menu appears.

Step 3. Press Yes to bypass calibration. (The menu will

automatically dismiss if no selection is made within 5
seconds.)

Step 4. Proceed with programming of starting address or other options.