Troubleshooting, Troubleshooting guide – Bad Boy Mowers BAD BOY 02.9812.0001C User Manual

Page 58

Advertising
background image

B

AD

B

OY

™ S

POT

L

UMINAIRE

U

SER

M

ANUAL

4 8

02.9812.0001C

Troubleshooting

Troubleshooting Guide

The following table provides a list of common start-up problems and possible solutions.

Symptom

Solution(s)

Refer to...

No power to luminaire.

Ensure power cable is properly connected to Neutrik
input connector.

page 10

Ensure power is switched on at source (mains, discon-
nect box, etc.)

n/a

No console control.

Ensure DMX512 or Ethernet data cable is properly
connected.

page 19

Ensure DMX512 address setting is correct.

page 23

DMX512 control not working cor-
rectly throughout daisy-chain.

Ensure data cables are correctly configured.

page 19

Ensure termination connector is installed at last lumi-
naire in data link.

page 12

Lamp does not strike at power-up.

Configure lamp to start at power-up.

page 34

Comm LED is red indicating that no
valid DMX or Ethernet signal is
detected.

Ensure DMX512 or Ethernet data cable is properly
connected.
Check console.

page 19

No Ethernet control.

Ensure that luminaire is not also receiving a DMX sig-
nal. If both valid DMX and Ethernet control are being
received, DMX control will take precedence.

page 22

Beam obstructed by gobo in open
position.

Set new gobo zero position.

page 46

Luminaire won’t take software
update.

Remove active control (DMX512 or Art-Net).

page 57

Advertising