14 Bryant

Section 3 — Maintenance

Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators

Figure 3.4 – Oil Drain Hose and Filter

3.4

CHANGING THE OIL FILTER

Change the engine oil filter as follows:
1. With the oil drained, remove the old oil filter by

turning it counterclockwise.

2. Apply a light coating of clean engine oil to the gasket

of the new filter. See Section 1.5.2 for recommended

filter.

3. Screw the new filter on by hand until its gasket lightly

contacts the oil filter adapter. Then, tighten the filter

an additional 3/4 to one turn (Figure 3.4).

4. Refill with the proper recommended oil (see Section

3.3.1). See Section 1.5.2 for oil capacities.

5. Start the engine and check for leaks.

3.5

CHANGING THE ENGINE
AIR CLEANER

3.5.1 7 KW, 12 KW AND 15 KW

GENERATORS

See Figures 1.1 and 1.2, for the location of the air

cleaner. Use the following procedure (Figures 3.5 & 3.6):
1. Turn the two screws counterclockwise to loosen.
2. Remove the cover and air filter.
3. Wipe away dust or debris from inside of the air box

and around edges.

4. Install the new air cleaner into the air box.
5. Install the cover. Turn the two cover screws

clockwise to tighten.

See the “Service Schedule,” Section 4.1, for air cleaner

maintenance. See Section 1.5.1 for air filter replacement

part number.

Figure 3.5 — 7 kW, Engine Air Cleaner Location

Figure 3.6 — 12 kW and 15 kW Engine

Air Cleaner

3.6

SPARK PLUG(S)

Reset the spark plug(s) gap or replace the spark plug(s)

as necessary. See Section 4.1 for maintenance

requirements.
1. Clean the area around the base of the spark plug(s)

to keep dirt and debris out of the engine. Clean by

scraping or washing using a wire brush and

commercial solvent. Do not blast the spark plug(s) to

clean.

2. Remove the spark plug(s) and check the condition.

Replace the spark plug(s) if worn or if reuse is

questionable. See Section 4.1 for recommended

inspection.

3. Check the spark plug gap using a wire feeler gauge.

Adjust the gap to 0.76 mm (0.030 inch) for 7 kW and

0.50 mm (0.020 inch) for 12/15 kW by carefully

bending the ground electrode (Figure 3.7).

Cover

Filter

Screw

Air Cleaner

Fuel

Regulator

‹

Oil Filter

Oil
Drain
Hose

Low Oil Switch

High Temp Switch

Loose

n

MAINTENENANCE

Screw

Advertising