PC control of the TV

• When a programme is set, the TV can be controlled

from the PC using RS-232C or IP. The input signal (PC/
video) can be selected, the volume can be adjusted and
various other adjustments and settings can be made,
enabling automatic programmed playing.

• Use an RS-232C serial control cable (cross type),

ETHERNET cable (commercially available) or wireless
LAN for the connections.

NOTE

• This operation system should be used by a person who

is accustomed to using PCs.

Communication conditions for IP

ETHERNET cable (commercially available)

Connect to the TV with the following settings made
for IP on the PC.

IP protocol

TCP/IP

Host IP address

Set the IP address on the TV
menu

Service

None (Do not select Telnet
or SSH)

TCP port#

Set a port number on the TV
menu (Control port)

When you set your ID and password on the TV
menu, you need to enter them as soon as you
connect to the TV.

NOTE

• The connection will be cut off when there has been no

communication for 3 minutes.

IP Control setup

1

Go to “Setup” > “View setting” > “Network Setup”
> “IP Control/Remote app” > “Control setting” >
“Change”.

2

To use IP Control, select “Enable”.

3

“Detail setting” > Set your login ID and password.

4

Set the port to use with IP Control.

5

Confirm the settings, and then press “OK”.

Communication conditions for RS-232C

RS-232C serial control cable (cross type)

(commercially available)

Set the RS-232C communications settings on the
PC to match the TV’s communications conditions.
The TV’s communications settings are as follows:

Baud rate

9,600 bps

Data length

8 bits

Parity bit

None

Stop bit

1 bit

Flow control

None

Communication procedure

Send the control commands from the PC via the
RS-232C connector.
The TV operates according to the received
command and sends a response message to the
PC.
Do not send multiple commands at the same time.
Wait until the PC receives the OK response before
sending the next command.
Make sure to send “A” with the carriage return and
confirm that “ERR” returns before operating.

Command format

Eight ASCII codes +CR

n

o

p

C1 C2 C3 C4 P1 P2 P3 P4

n

Command four digits: Command. The text of
four characters.

o

Parameter four digits: Parameter 0

_9, blank, ?,

minus

p

Return code (0DH):

?

Parameter

Input the parameter values, aligning left, and fill with
blank(s) for the remainder (be sure that four values
are input for the parameter).
When the input parameter is not within an adjustable
range, “ERR” returns (refer to “Response code
format”).

0

0

5

5

1

0

0

0

0

0

9

0

When “?” is input for some commands, the present
setting value responds.

?

?

?

?

Response code format

Normal response

Problem response
(communication error or
incorrect command)

O

K

E

R

R

Return code (0DH)

Return code (0DH)