Rating plate – Bakers Pride VH1828E User Manual

Page 14

Advertising
background image

1.

Check to see if the main circuit breaker is ON at the breaker panel.

2.

Check the (2) 5-amp fuses located in the bottom of the Power Control Box

3.

Check that the Main Switch is ON. If operating properly, the rocker switch will be lighted

when ON.

4.

Check the setting of the temperature control thermostats (knobs). If operating properly, they

will activate the amber indicator lights as you turn the knobs back and forth, calling for heat. It

is very unlikely that the light will burn out.

5.

If there is no air blowing, check the following:

:

the unit by turning the Main Switch OFF

for at east15 seconds and then turning it back ON. This resets the blower speed

controls. If this is not successful, turn off the wall circuit breaker for one minute and

then turn it on again.

: Observing the

at the beginning of this

section, open the Power Control Box and locate the overload relay (above

gearmotor).

. Try the Main Switch again.

1.

NOTE:

, meaning that if one or both of the blower motors get jammed, the

overload relay shuts the motor(s) OFF if there is excessive current going to

the motor(s), or if excessive heat builds up in the overload relay due to an

overload condition. Because it takes time for the relay to cool down, do not

assume that there is another problem IF pushing the RESET button doesn't

accomplish the task Both settings,

, must be correct for proper operation.

If the conveyor belt does not move, check to see that the coupling setscrew is tight on the

gearmotor output shaft.

If the oven still does not operate, turn OFF the Main Switch and disconnect the power supply to the

unit (if possible). Contact the factory, factory representative, or an authorized service agency.

.

.

i.

RESET

ii.

PUSH IN THE “RESET” BUTTON

The Overload Relay is both a current limiting and a thermal

device

RESET button pushed IN & overload

not overheated

6.

CAUTION

IF FUSES ARE BAD, REPLACE ONLY WITH IDENTICAL FUSES.

DO NOT

SUBSTITUTE HIGHER VALUE FUSES, AS THIS MAY NULLIFY NEEDED PROTECTION

FOR THE INTERNAL ELECTRICALCOMPONENTS.

DUALAIR MODEL VHVA-SERIES

DUAL AIR MODEL VH-SERIES

WARNING

ALL SERVICING SHOULD BE PERFORMED ONLY BY A FACTORY AUTHORIZED SERVICE

TECHNICIAN ORAGENT

:

12. RATING PLATE

A copy of the rating plate is shown here for reference.

MODEL VH-SERIES

MODEL VHVA-SERIES