Field Connections

a)

b)
c)

d)

MUST

ONLY.

Remove the cover from the Power Distribution Box Panel (

on right side when

facing front of unit).
Locate the 4-pole Power Distribution Terminal Block mounted in the Power Distribution Box.
Install the proper strain relief for the

utilizing the knock-out hole

provided. The strain relief should be securely fastened.
Supply the proper conduit to the conveyor oven and connect through the strain relief. Connect

properly-sized, copper-only conductor wires (rated 90°C) to the Power Distribution Terminal Block in

accordance with the schematic shown on the rating plate, as well as the wiring diagram provided.

NOTE: For three-phase connections, if any “High Voltage Leg” conductor is present, it

be

mounted to L3

Replace the cover and fasten securely with removed screws.

under the control box

PERMANENT CONNECTION

NOTE: VERIFY THAT INPUT POWER MATCHES THE OVEN POWER REQUIREMENTS STATED

ON THE RATING PLATE, WHICH IS LOCATED ON THE POWER CONTROL BOX.
IF INPUT VOLTAGE DOES NOT MATCH OVEN VOLTAGE REQUIREMENTS, THE CORRECT

CONVEYOR OVEN MUST BE INSTALLED. THE CONVEYOR OVEN CANNOT BE MODIFIED IN THE

FIELD TO MATCH INPUT POWER.
CAUTION:

VERIFY VOLTAGE OF EACH LEG. IF ANY LEG HAS A

VOLTAGE GREATER THAN 240V THIS LEG MUST BE CONNECTED TO L-3 ON THE POWER

DISTRIBUTION BLOCK.
FOR DUALAIR MODELS VH1620E, VHVA1620E:

FOR DUALAIR MODELS VH1828E, VHVA1828E:

FOR 3 PHASE UNITS ONLY:

These units are supplied with a flexible power cord, according to the specification placed with the

original order, which specified either single-phase or three-phase operation. No internal field

connection is necessary. All internal connections are complete. Connect the power cord to the

proper power receptacle. (see diagram below).
Note: If a different power cord is required than supplied, the correct power cord must be obtained

from a factory authorized service agent. Only an authorized service agent is to replace a power

cord.

%

G

L3

L2

L1

G4

R (BROWN)

L2

L2

L2

5

E (BROWN)

4

A

FA

CT

O

RY

W

IR

IN

G

TO

IN

TE

RN

AL

CI

RC

UI

TS

FI

EL

D

W

IR

IN

G

SE

RV

IC

E

CONNE

CT

IO

NS

SINGLE-PHASE CONNECTION

G

L3

L2

L1

G4

R (BROWN)

L2
L2

L2

5

E (BROWN)

4

A

FI

EL

D

W

IR

IN

G

SE

RV

IC

E

CONNE

CT

IO

NS

FA

CT

O

RY

W

IR

IN

G

TO

IN

TE

RN

AL

CI

RCUI

TS

THREE PHASE CONNECTION

NEMA SPECS.

1620E 3 PHASE

1620E 1 PHASE

6-50P

L15-30P

Advertising
This manual is related to the following products: