THE PROBLEM

THE CAUSE

THE SOLUTION

No air or not

enough air coming

from blower(s)

(Continued)

7. If all previous tests are normal, then

blower motor has failed. Replace.

Blower motor(s) failed

ON, disconnect main power cord or circuit

breaker for 1 minute. If "FAULT" light

persists, and all previous tests show

normal, speed control can be tested in the

following manner: swap motor wires from

"good" speed control to "bad" control, and

see if blower motor works. If YES, then

"FAULTY" control is bad and needs

replacing. If NO, then "FAULTY" control is

OK, and motor may need replacing.

6. Test potentiometer by swapping "bad"

pot to "good" speed control. If motor then

works properly, pot is OK, and other speed

control needs testing. (model VHVA-Series

only).

Wire connections broken or loose between

potentiometer and speed control

at the header terminal on speed control

board.

4. One pot wire contains a 15K ohm

resistor at the pot body. Verify this solder

connection is good.

Blower speed control(s) failed

5. Blower(s) can stop if speed controls

have not been reset (model VHVA-Series

only). If yellow "FAULT" light on speed

control circuit board is ON, first turn OFF

main Switch for 15 seconds to rest

control(s). If yellow "FAULT" light remains

CAUTION: THE FOLLOWING TESTS 1-

4 ARE PERFORMED WITH LIVE POWER

WITH CONTROL BOX OPEN, OR REAR

MOTOR COVER REMOVED. THESE

TESTS TO BE PERFORMED ONLY BY

AN AUTHORIZED SERVICE AGENT.

1. Speed control wire connections are

labeled U, V, and W. Insure connectors

are tight.

2. Insure these (3) wires are tight on

terminal block located in blower motor

compartment.

3. Tighten wires from pot to speed control

Wire connections broken or loose between

blower motor(s) and terminal block.

Wire connections broken or loose between

speed controls and blower motor(s)

(model VHVA-Series only)