17. TEMPERATURE CONTROL CONVERSION CHART

The temperature sensor (probe) that is supplied with this conveyor oven is an RTD type, which yields an

output based on Ohms of resistance. This particular RTD device has a linear resistance curve that

produces a very predictable amount of resistance that can be converted to degrees Fahrenheit. This

particular device produces a resistance increase of 2 Ohms per every 1 degree F. The baseline value is

approx. 1000 ohms at 32 °F (0°C).

Ohms

°F

Ohms

°F

Ohms

°F

1002

32

1358

204

1714

380

1004

34

1370

210

1722

384

1017

40

1379

214

1734

390

1025

44

1391

220

1742

394

1038

50

1399

224

1753

400

1046

54

1411

230

1761

404

1059

60

1420

234

1773

410

1067

64

1432

240

1781

414

1080

70

1440

244

1793

420

1088

74

1452

250

1801

424

1101

80

1460

254

1813

430

1109

84

1473

260

1821

434

1122

90

1481

264

1832

440

1130

94

1493

270

1844

446

1143

100

1501

274

1852

450

1151

104

1513

280

1860

454

1164

110

1521

284

1872

460

1172

114

1533

290

1879

464

1184

120

1541

294

1891

470

1193

124

1554

300

1899

474

1205

130

1562

304

1911

480

1214

134

1574

310

1918

484

1226

140

1582

314

1930

490

1234

144

1594

320

1938

494

1247

150

1602

324

1950

500

1255

154

1614

330

1957

504

1267

160

1622

334

1969

510

1276

164

1634

340

1977

514

1288

170

1642

344

1988

520

1286

174

1654

350

1996

524

1309

180

1662

354

2008

530

1317

184

1674

360

2027

540

1329

190

1682

364

2035

544

1338

194

1694

370

2046

550

1350

200

1702

374

!