Mdi and mdi-x connections, Mdi and mdi-x connections -3, Figure 4-1 – Bay Technical Associates BayStack 304 User Manual

Page 83: Mdi-x to mdi cable connections -3, Mdi and mdi-x, Connections

Advertising
background image

Troubleshooting and Diagnostics

893-01010-A

4-3

MDI and MDI-X Connections

BayStack switches use MDI-X ports that allow you to connect directly to end
stations without using crossover cables (see

Figure 4-1

). Ports that implement the

crossover function internally are known as MDI-X ports (where “X” refers to the
crossover function).

Figure 4-1.

MDI-X to MDI cable connections

Note:

For the transmitter of one device to connect to the receiver of another

device, the sum of crossovers must always be an odd number.

1

8

1

8

8

1

8

1

RX+

RX-

TX+

TX-

TX+

TX-

RX+

RX-

MDI-X port

BayStack 303/304 switch

End station

Straight-through cable

MDI port

T

R

T

R

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

617EB

89301010.BK Page 3 Tuesday, June 10, 1997 8:00 PM