Using the BayStack 303 and 304 Ethernet Switches

B-4

893-01010-A

Installing an MDA

The expansion slot on the BayStack 303 or 304 switch accommodates a small
media dependent adapter that provides one high-speed port connection. The
connection can be either an RJ-45 10/100BASE-TX MDA or a fiber
100BASE-FX MDA with an SC connector.

To install an MDA into the expansion slot, follow these steps:

1.

Unplug the AC power cord from the back of the switch.

2.

Remove the filler panel over the expansion slot.

Table B-2.

100BASE-TX MDA LEDs

Label

Color

State

Meaning

Link

Green

On

Off

Link is active and connected correctly.

Link is inoperative or improperly connected.

100

Green

On

Off

Port is operating at 100 Mb/s.

Port is operating at 10 Mb/s.

F Dx

Green

On

Off

Port is operating in full-duplex mode (200 Mb/s).

Port is operating in half-duplex mode (100 Mb/s).

Warning:

The switch must be taken offline and have all power removed prior

to installing the MDA. Failure to remove power can result in damage to
sensitive components and void all equipment warranties.