Bay Technical Associates V79 PDI-1 User Manual

Page 24

Advertising
background image

20

For example, if the PDI is installed in a non-cascaded unit as Module 2 and you are
using the default port select code ($BT), send

$BT2<cr>$CONFIG<cr>

to enter

into configuration mode. No characters should be typed between $BT2<cr> and
$CONFIG<cr>. If this happens, the entire configuration sequence will be
discarded and you will have to send the configuration sequence again.

NOTE:

All commands must be in uppercase.

To access the menu-driven configuration mode of the PDI from the service port,
use the following procedure:

1.

Connect a terminal to the EIA-232 service port and configure the
terminal's serial parameters to 9600 baud rate, 8 word size, 1 stop bit, and
no parity.

2.

Connect to the PDI by sending

$BAYTECH

, the desired module number (2

to 16), and Carriage Return or Line Feed.

3.

Access configuration mode by sending

$CONFIG<cr>

. Following the

example on the previous page, you would send

$BAYTECH2<cr>$CONFIG<cr>

to configure Module 2.

NOTE:

All commands must be in uppercase.

Advertising