FRONT PANEL CONFIGURATION

The LCD display and associated front panel controls can provide the configuration
status of the PDI. All the parameters shown in the LCD status message are fully
described in Section 5.1.

When the M8/M16 DAC has completed its power-up self-test, the following menu
will be displayed on the LCD:

Bay Technical Assoc

Select Module

00

NOTE:

The following LCD screens are examples and will vary depending upon

current configuration status.

To review the configuration status of the PDI installed as Module XX (XX = 02 to
16), use the

>

or

?

keys to highlight "Module XX" from the M Series main menu

screen and press the SELECT key. The LCD will respond with a menu similar to
the following for the PDI-1:

V78 PDI-1 MODULE XX

Display Status

Exit Module Menus

Select "Display Status" the LCD will respond with:

Debounce Delay 10

Latch Polarity HI/LO

Report Method COMMAND

76

-PAGE SELECT-EXIT

Pressing the

>

or

?

keys scrolls through the following entries:

Report Interval HH:MM

Host Address 1:1,1

Time Tagging ENABLE

Term Characters 0D0A

Dyna Cfg Cmd ENABLE

To exit the configuration status mode, press the SELECT key at any time. You
are returned to the PDI's LCD main menu. Next, press either arrow key until the
cursor is located on the "Exit Module Menus." Pressing the SELECT button
returns you to the main M Series LCD menu.