4.5 Trigger Submenu

After accessing the Trigger menu, use the

arrow keys to move cursor between the various

menu entries. Use the

rotary knob

to toggle the selected entry value or to change selected digit. The

display shows up as following.

Figure 4-k Trigger Submenu

Select SOURce: IMMediate, EXTernal, BUS (SCPI command), KEY (RF on/off button)

Select SLOPe: POSitive, NEGative

Select CONTinuous: ON, OFF (ON means that the trigger is re-armed after each trigger occurrence)

Select RETRigger: OFF, ON, IMMediate (OFF means that any trigger event during execution of list is

ignored)

Enter DELAY: trigger delay in microseconds.

Press the

RF On/Off button

to arm the trigger. Exit the menu by pressing the

menu key

.

4.6 LF OUTPUT Submenu

In the LF OUTPUT Submenu the FUNCT OUT output can be configured at the rear panel of

the instrument.

Press the

RF On/Off button

to turn the output on and off. Exit the menu by pressing the

menu key

.

On the first screen the source for the FUNCT OUT can be selected. Choose LFG for the low

frequency generator, TRIG to enable the instrument trigger output and PULM to enable the

pulse video output. If LFG is selected, use the

arrow to proceed to the second display.

Select waveform between sine, triangle, or square. Then enter the desired output frequency

and voltage amplitude.