To change a mapping, select the auxiliary number from the 8 available, press right to select,

sand then scroll through the available functions using up and down control inputs.

5.8

Alarms Menu

The Alarms menu allows you to turn on and off alarm-related settings, learn alarm positions,

and set the status of the two (2) alarm relays.

Learn alarm pos reacts differently depending on the current alarm mode. If Auto Alarm is on

and Multi Alarm is off, this function saves the single Alarm Pos, which would be activated if

the tamper switch is triggered. If Multi Alarm is on, you can select which alarm position to

save by selecting Right, toggling up and down to the desired number, and then Right again to

save.

A MIC power supply has a single tamper switch / alarm input built in; however, if more are

required, a multi alarm plug-in board with 8 inputs and a washer drive function is available.

Along with the 8 inputs, the multi alarm card also features 2 output relays, which can be used

to either reset the activated alarm, or provide a signal to some other equipment.

The following settings control the behavior of the MIC 500 Series Camera as it detects

different alarm signals.

Aux Number

Function

1

Auto Focus

2

Digital Zoom

3

Auto Iris

5

Wiper

6

Washer

7

OSD

8

Backlight

MAIN MENU

1/2

..ALARMS..

1/2

..ALARMS..

2/2

MIC SETUPS

AUTO ALARM

OFF

RELAY 2 STATUS:

ACTIVATE FEATURE

MULTI ALARM

OFF

SET WITH ALARM 5-8

PRESET TOUR

ALARM REARM

60 S

NORMALLY CLOSED

PATTERN TOUR

MANUAL CONTROL

PRESETS

LEARN ALARM POS

COMMUNICATIONS

RELAY 1 STATUS

ADVANCED SETUPS

SET WITH ALARM

1-4

ALARMS

NORMALLY CLOSED

Menu Item

Description

Options

AUTO ALARM

Enables use for both single or multi alarm functionality. With Auto Alarm

on and Multi Alarm off, the unit monitors the tamper switch line, moving

to the programmable Alarm Position when the connection is grounded.

If Auto Alarm is turned off, the camera ignores any changes in the status

of the tamper line.

ON/OFF

MULTI ALARM

Enables you to set up a separate position for each of the eight (8) alarm

inputs. Any given alarm input triggers the camera to move to the

position to which it is associated. To enable this function, turn on Auto

Alarm and Multi Alarm.

ON/OFF

ALARM REARM

See Section 5.8.1 Alarm Relays and Re-arm Time, page 35.

1/5/10/60 sec.